Standard · California, United States
California TB 117-2013: what it tests and what it means for FR finishing
In short: TB 117-2013 is California's smolder-resistance test for cover fabrics, barrier materials, resilient fillings and decking used in upholstered furniture sold in the state. It uses a lighted cigarette; it is not an open-flame test.
What the bulletin tests
TB 117-2013, issued in June 2013 by California’s Bureau of Household Goods and Services (BHGS), tests the smolder resistance of cover fabrics, barrier materials, resilient filling materials and decking materials used in upholstered furniture.
The cover-fabric method in brief
- A lighted, non-filtered cigarette, covered with standard sheeting, is placed on a seat-and-back mock-up.
- A cover-fabric mock-up fails if it continues to smolder after 45 minutes, if vertical char on the cover exceeds 1.8 inches (45 mm), or if it transitions to open flaming.
- Three mock-ups are tested initially; if one fails, three more are tested, and any further failure fails the cover (§1.4).
- A cover that fails Section 1 may still be used together with a barrier material that passes Section 2 (§2.1).
Dates and scope
Per the BHGS FAQ, TB 117-2013 became effective on 1 January 2014, was fully implemented on 1 January 2015, and applies to upholstered furniture sold in California. Manufacturers are no longer compelled to make products open-flame resistant, as they were under the previous TB 117.
What this means for the finisher
A smolder result says nothing, on its own, about open-flame performance. If the same fabric also goes to the UK, read BS 5852 and the UK regulations and our article TB 117-2013 vs the UK furniture fire tests. We do not currently position a specific product against TB 117-2013; ask us about your fabric.
Frequently asked questions
Is TB 117-2013 an open-flame test?
No. Section E.2 of the bulletin states that the methods are not intended to measure performance under open-flame exposure. The BHGS FAQ adds that manufacturers must only meet the cigarette smoldering resistance tests.
When does a cover fabric fail TB 117-2013?
A cover-fabric mock-up fails if it continues to smolder after 45 minutes, if vertical char exceeds 1.8 inches (45 mm), or if it transitions to open flaming.
When did TB 117-2013 take effect?
According to the BHGS FAQ, it became effective on 1 January 2014 and was fully implemented on 1 January 2015.
Sources
- California BHGS: Technical Bulletin 117-2013 (official PDF, June 2013)
- BHGS: Frequently Asked Questions, TB 117-2013 (revised June 2019)
Sources last checked: 12 November 2026.