Flame Retardants Know-how
TB 117-2013 vs the UK Furniture Fire Tests: Why One Upholstery Fabric May Need Two FR Approaches
Key takeaways
- A cover fabric that meets California TB 117-2013 has been assessed against a smouldering cigarette, not an open flame.
- In the UK, upholstery needs the cigarette test, and any visible permanent cover must also pass the match test using butane flame ignition source 1.
- UK covers treated with a fire-retardant chemical are water-soaked before both tests, so finish durability matters.
- Treat California and the UK as two specifications: write market, method and ignition source on the purchase order.
Short answer: a cover fabric that meets California Technical Bulletin 117-2013 has been assessed against a smouldering cigarette, not an open flame. The UK Furniture and Furnishings (Fire) (Safety) Regulations 1988 also require a cigarette test, but a visible permanent cover must additionally pass a match test using butane flame ignition source 1, and covers treated with a fire-retardant chemical are water-soaked first. If you sell the same upholstery quality into California and the United Kingdom, treat them as two specifications, not one finish.
What does California TB 117-2013 actually test?
TB 117-2013 was issued in June 2013 by California’s Bureau of Household Goods and Services (BHGS). It tests the smolder resistance of four groups of materials used in upholstered furniture: cover fabrics, barrier materials, resilient filling materials and decking materials.
For cover fabrics, the method places a lighted, non-filtered cigarette, covered with standard sheeting, on a seat-and-back mock-up. A cover-fabric mock-up fails if:
| Fail criterion (cover fabric, §1.4) | Limit |
|---|---|
| Continues to smolder | after 45 minutes |
| Vertical char on the cover | more than 1.8 inches (45 mm) |
| Transition to open flaming | any |
Three mock-ups are tested at first. If one fails, three more are tested, and any further failure fails the cover. A cover that fails this section may still be used together with a barrier material that passes the barrier test in Section 2.
Two points are easy to miss:
- It is not an open-flame test. Section E.2 of the bulletin says the methods are not intended to measure performance under open-flame exposure.
- The previous TB 117 was different. The BHGS FAQ states that manufacturers must only meet the cigarette smoldering resistance tests and are no longer compelled to make products open-flame resistant, as they were under the previous TB 117. TB 117-2013 became effective on 1 January 2014, was fully implemented on 1 January 2015, and applies to upholstered furniture sold in California.
What does the UK require?
In the United Kingdom, the legal requirements for domestic upholstered furniture sit in the Furniture and Furnishings (Fire) (Safety) Regulations 1988. The test methods they name come from BS 5852. The current BSI methods standard is BS 5852:2006, which BSI describes as assessing covers and fillings, or complete seating, against a smouldering cigarette or flaming ignition sources. The 1988 Regulations still cite BS 5852: Part 1 and Part 2, so it is worth confirming which reference your buyer actually uses.
| UK requirement | What the Regulations say |
|---|---|
| Cigarette test (regulation 5, Schedule 4) | Upholstery, except mattresses, bed-bases, pillows and cushions, must pass the smouldering cigarette test in BS 5852: Part 1, as modified by Schedule 4 |
| Match test (regulation 8, Schedule 5) | Any visible part of the permanent cover on filled furniture must pass the match test, using the BS 5852: Part 1 provisions for butane flame ignition source 1 |
| Fillings (regulation 6, Schedule 1) | Filling materials must pass the relevant ignitability test; polyurethane foam in slab or cushion form is tested with an ignition source 5 crib under BS 5852: Part 2 |
| Water soak (Schedules 4 and 5) | A covering fabric treated with a fire-retardant chemical goes through a prescribed water-soaking procedure before conditioning and testing |
The Regulations were amended in 2025. The Office for Product Safety and Standards says the amendment came into force on 30 October 2025 and changed scope for certain baby and children’s products, display labels and the time limit for legal proceedings. It did not change the cigarette, match or crib test methods described above.
Why might one fabric need two finishing approaches?
The ignition sources are different
TB 117-2013 is a smolder test. The UK cover requirement adds an open-flame match test, and UK polyurethane foam is challenged with a wooden crib. A finish that keeps a cigarette from smouldering through a California mock-up has not, by that result alone, been shown to resist an open flame. The bulletin says so itself.
Pre-treatment is different
A chemically treated cover bound for the UK is water-soaked before the official tests. A finish that performs well on a fresh sample can behave differently after the soak. That makes durability part of the chemistry decision:
- A non-durable finish is generally chosen for articles that are not soaked or laundered.
- A semi-durable finish, such as our FR-S01 for cotton and cellulose fabrics, is designed to resist a soak test.
- Back coating keeps the flame retardant in a binder layer on the reverse of the cover. Our FR-5852 (synthetic upholstery) and FR-T235 (cotton and natural fibers, non-halogen) are designed with BS 5852 in mind.
The documentation is different
Do not send one report to both buyers. For the UK, confirm that the cigarette and match tests were run and whether the cover was water-soaked. For California, confirm TB 117-2013 and which component (cover, barrier, filling or decking) was tested.
A purchase-order checklist for FR upholstery
- Destination market: California, the UK, or both.
- Exact method and edition: “TB 117-2013”, or the UK cigarette and match tests under the 1988 Regulations, not just “BS 5852”.
- Ignition source(s): cigarette only, or cigarette plus butane flame ignition source 1.
- Component tested: cover, barrier, filling or decking.
- Pre-treatment: water soak or washing before the test.
- Chemistry constraints: for example, halogen-free required or not.
- Who tests, and on which sample: the exact quality, colour and finishing lot you will ship.
Where our products fit
On our product list, FR-5852 is a coating paste for synthetic upholstery fabric, designed to target BS 5852. FR-T235 is a non-halogen flame retardant slurry for cotton and other natural fiber fabrics that can be blended into binders, designed with BS 5852 in mind. FR-S01 is a semi-durable finish for cotton and cellulose fabrics designed to resist a soak test.
These are design targets, not certificates, and not a claim that any fabric will pass. Test the quality you will ship against the method the buyer names. If you are finishing the same upholstery quality for California and the UK, send us the fabric details and both requirements, and we will suggest a starting point for your lab trials.

Frequently asked questions
Does passing TB 117-2013 mean a fabric is flame resistant?
Not against an open flame. TB 117-2013 tests smolder resistance with a lighted cigarette, and Section E.2 of the bulletin says its methods are not intended to measure performance under open-flame exposure.
Can I use one test report for buyers in California and the UK?
Usually not. The UK cover requirement adds an open-flame match test, and treated covers are water-soaked first. Ask each buyer for the method and ignition source, and test accordingly.
Is the cigarette called ignition source 0 in the UK regulations?
The 1988 Regulations call it the smouldering cigarette test in BS 5852: Part 1. We use the wording of the official text.
Did the 2025 UK amendment change the test methods?
According to the Office for Product Safety and Standards, the 2025 amendment, in force from 30 October 2025, changed scope for certain baby and children's products, display labels and the time limit for legal proceedings, not the cigarette, match or crib test methods.
Sources
- California BHGS, Technical Bulletin 117-2013 (official PDF, June 2013)
- BHGS, Frequently Asked Questions: TB 117-2013 (revised June 2019)
- The Furniture and Furnishings (Fire) (Safety) Regulations 1988, S.I. 1988/1324
- 1988 Regulations, Schedule 4: The Cigarette Test
- 1988 Regulations, Schedule 5: The Match Test
- 1988 Regulations, Schedule 1: filling materials (ignition source 5 crib)
- BSI Knowledge: BS 5852:2006
- OPSS: Furniture and Furnishings (Fire) (Safety) (Amendment) Regulations 2025